Autonomic Nervous System Function and Depth of Sedation in Ddults Receiving Mechanical Ventilation

    loading  Checking for direct PDF access through Ovid

Abstract

Background

The effect of the depth of sedation on the function of the autonomic nervous system is not well known.

Objectives

To describe the effect of level of sedation on heart rate variability as a marker of the function of the autonomic nervous system in patients receiving mechanical ventilation.

Methods

This pilot study was part of a larger study in which sedation level was measured continuously for up to 24 hours. The sample consisted of 14 patients receiving mechanical ventilation. The R-R interval was measured continuously via electrocardiography. Sedation level was determined by using the Patient State Index and was categorized as deep (<60) or light (≥60). Continuous heart rate data of 5 to 10 minutes for each sedation level for each patient were analyzed.

Results

Parasympathetic activity as indicated by root mean square of successive difference of the R-R interval, the highfrequency component, and the percentage of differences of successive N-N intervals (intervals due to normal sinus depolarization) that differed more than 50 milliseconds was significantly lower for deep sedation than for light sedation. The markers indicating sympathetic activity, including the lowfrequency component and the ratio of the low-frequency component to the high-frequency component, did not differ significantly between the 2 levels of sedation. Most patients were receiving benzodiazepines.

Conclusions

Deep sedation may be associated with depression of parasympathetic function in patients receiving mechanical ventilation. Use of benzodiazepines most likely contributed to this finding. (American Journal of Critical Care. 2009;18:42–51)

Related Topics