Cardiac performance in response to PEEP in patients with cardiac dysfunction


    loading  Checking for direct PDF access through Ovid

Abstract

The effect of PEEP on cardiac performance was evaluated in 21 patients with left ventricular (LV) dysfunction. Twenty-three data sets were divided into three groups according to pulmonary arterial wedge pressure (PAWP). In three of four group A data sets (PAWP = 12 mm Hg), cardiac output (CO) decreased when PEEP was added. In four of six group B data sets (PAWP = 14–18 mm Hg) and in 12 of 13 group C data sets (PAWP ≥ 19 mm Hg), CO increased with addition of PEEP. In group C, the mean increase in CO was 500 ml/min, and the mean level of best PEEP was 3.9 cm H2O. When PAWP exceeded 18 mm Hg, PEEP was safe and in many instances augmented CO.