Automated intensive care unit risk adjustment: Results from a National Veterans Affairs study


    loading  Checking for direct PDF access through Ovid

Abstract

ContextComparison of outcome among intensive care units (ICUs) requires risk adjustment for differences in severity of illness and risk of death at admission to the ICU, historically obtained by costly chart review and manual data entry.ObjectiveTo accurately estimate patient risk of death in the ICU using data easily available in hospital electronic databases to permit automation.Design and SettingCohort study to develop and validate a model to predict mortality at hospital discharge using multivariate logistic regression with a split derivation (17,731) and validation (11,646) sample formed from 29,377 consecutive first ICU admissions to medical, cardiac, and surgical ICUs in 17 Veterans’ Health Administration hospitals between February 1996 and July 1997.Main Outcome MeasuresMortality at hospital discharge adjusted for age, laboratory data, diagnosis, source of ICU admission, and comorbid illness.ResultsThe overall hospital death rate was 11.3%. In the validation sample, the model separated well between survivors and nonsurvivors (area under the receiver operating characteristic curve = 0.885). Examination of the observed vs. the predicted mortality across the range of mortality showed the model was well calibrated.ConclusionsAutomation could broaden access to risk adjustment of ICU outcomes with only a small trade-off in discrimination. Broader use might promote valid evaluation of ICU outcomes, encouraging effective practices and improving ICU quality.