Symbol

    loading  Checking for direct PDF access through Ovid

Abstract

BACKGROUND:

Due to dentition defect, dentition loss, periodontal disease, trauma and tumor, many patients have to face insufficient buccal-lingual mandibular width. At present, there is no consistent conclusion in suitable peri-implant buccal-lingual mandibular width.

OBJECTIVE:

To investigate the stress of implant-bone interface with three-dimensional finite element method, in order to evaluate buccal-lingual mandibular width suitable for implants.

METHODS:

Classes I and III mandible implant models (the buccal-lingual width of implant neck region was 1, 1.5, 2, 2.5, 3 and 3.5 mm) were loaded with 200 N forces vertically and at 60° oblique. Then, the stress and strain in the implant-bone interfacial were analyzed.

RESULTS AND CONCLUSION:

Almost 2 mm or more than 2 mm of mandible bone width could result in good stress distribution in implant-bone interface. The stress distribution of oblique loading was much greater than that of vertical loading. Proper quantity of peri-implant mandibular width is good for stress distribution in implant-bone interface. In the clinical treatment, the oblique loading should be avoided or reduced.