INADVERTENT INTRA-ARTERIAL CANNULATION IN THE EMERGENCY DEPARTMENT: FEASIBILITY OUTCOMES FROM A PILOT STUDY

    loading  Checking for direct PDF access through Ovid

Abstract

Objectives & Background

Inadvertent intra-arterial cannulation (IIAC) occurs in some Emergency Department (ED) patients. Interpretation of point of care blood gas analysis (BGA) by a senior emergency physician (EP) may be used to screen for this. We conducted a prospective observational pilot study to investigate the rate of IIAC in the ED setting and to explore feasibility questions to inform a future larger study.

Objectives & Background

Objectives:

Methods

Five medical students and FY1 doctors received a two-hour training session from an EP in US assessment of peripheral cannula location. Competence was confirmed by five observed US assessments. Data collectors performed US assessment of cannulas inserted in a convenience sample of ED patients over a two week period (83 patients). Their confidence and time taken to complete US assessment were recorded. Routine BGA obtained during cannula insertion were shown to an EP whose confidence in interpretation was recorded. Data collectors completed a survey to record their experience of various aspects of the study.

Results

100% of data collectors found using ultrasound to determine the location of a cannula to be 'very easy' or 'quite easy'. Adequate US views were obtained in 94% of examinations. Mean duration of US assessment was 11 minutes 25 seconds. 87% of cannulae had a routine BGA taken and EPs were 'quite confident' or 'very confident' in their interpretation in 97% of BGAs. There was no difference in blood gas values between different insertion sites.

Conclusion

Junior doctors and medical students can be trained in US assessment of cannula placement. BGA is frequently performed during cannula insertion. EPs interpret BGA confidently. Insertion site does not complicate interpretation. It is feasible to use this methodology for larger studies.