Application of Time-lapse Photography to the Apportionment of Personnel Exposure During Cardiac Catheterization

    loading  Checking for direct PDF access through Ovid

Abstract

During cardiac catheterization procedures, personnel receive relatively high radiation exposure. In order to evaluate what phases of the procedure produces the most exposure, a technique for calculating X-ray exposure to the eyes and thyroids of physicians performing such examinations was developed. This technique uses time-lapse photography to determine the position of the selected anatomical sites in time and space. A computer program is used to combine this spatial and temporal information with a model of exposure rates in space, enabling calculation, integration and accumulation of exposure per procedure during an entire procedure. For the primary cardiologist, the average exposures calculated by the developed technique were 29.2 mR for the eye and 25.1 mR for the thyroid, which compares well with the TLD measurements of 27.8 and 23.8 mR, respectively. For the assistant cardiologist, the average calculated values were 14.2 and 12.4 mR for eye and thyroid as compared to 9.3 and 6.5 mR, respectively, measured with TLDs. Approximately 30–70% of eye and thyroid exposures were received during the cine portions of the procedures. These exposure values agree well with previous studies