Constrained liners for recurrent dislocations in total hip arthroplasty


    loading  Checking for direct PDF access through Ovid

Abstract

ABSTRACT:This study reports the results and complications from treating recurrent hip dislocations with a constrained liner (CL) after total hip arthroplasty (THA).Forty patients who had a CL inserted as a secondary prophylactic treatment were retrospectively reviewed after a median observation period of 27 months (range 7-77 months).During the observation period five patients had to be revised: one for deep infection and four on account of re-dislocations.Our results indicate that patients with recurrent THA dislocations can be treated with a CL and has a satisfactory low complication rate and a relatively low risk of re-dislocation.