Intractable Pneumothorax Treated With Endobronchial Watanabe Spigots

    loading  Checking for direct PDF access through Ovid

Abstract

Pneumothorax secondary to nontuberculous mycobacterial lung disease is often intractable and associated with high mortality. An endobronchial Watanabe spigot (EWS) is a silicon plug developed for bronchoscopic bronchial occlusion. Here we report a case of intractable pneumothorax secondary to nontuberculous mycobacterial lung disease successfully treated using EWSs. Occlusion of the multiple ectatic bronchi connected to the bronchopleural fistula was essential for optimal effect of the EWSs.