Detection and Localization of Bile Duct Leaks After Cholecystectomy Using Gd-EOB-DTPA—Enhanced MR Cholangiography: Retrospective Study of 16 Patients

    loading  Checking for direct PDF access through Ovid

Abstract

Objective

To determine if gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance (MR) cholangiography can detect and localize bile duct leaks in postcholecystectomy patients.

Material and Methods

Four blinded independent radiologists performed a retrospective review of 16 consecutive patients who underwent MR cholangiography with intravenous Gd-EOB-DTPA for the evaluation of possible biliary leak. Image quality, ductal opacification, and presence and location of any bile leak were evaluated. An independent observer determined the criterion standard using a consensus of all chart, clinical, and imaging findings.

Results

All 6 bile leaks confirmed at endoscopic retrograde cholangiopancreatography were diagnosed by all reviewers (sensitivity, 100%). Of the 10 patients with no leak, only one reader incorrectly diagnosed a bile leak in a single case (specificity, 98%). The accuracy for detection of the site of leak with Gd-EOB-DTPA-enhanced MR cholangiography was 80%.

Conclusion

Gadolinium-EOB-DTPA–enhanced MR can detect bile leaks with a high sensitivity and specificity.