Comparing the Push-Pull Versus Discard Blood Sample Method From Adult Central Vascular Access Devices

    loading  Checking for direct PDF access through Ovid

Abstract

This study demonstrates the feasibility of replacing the discard blood sampling method for central vascular access devices with the push-pull method. A comparative, within-subject design was used to evaluate 61 unique, paired blood samples from 1 adult outpatient oncology clinic. A 21-measure laboratory panel was conducted on each of the paired samples. Interpretation showed a small mean bias and excellent agreement between the methods. Blood samples obtained using the push-pull method were within clinically acceptable ranges. No hemolysis was noted by laboratory evaluation of 59 samples.