Successful Laser-Assisted Removal of an Infected ICD Lead with a Large Vegetation

    loading  Checking for direct PDF access through Ovid

Abstract

Infective endocarditis involving transvenous pacing leads is an uncommon but potentially lethal complication of implantable cardioverter-defibrillator (ICD) implantation. Complete removal of the device and the leads is presently considered to be the optimal treatment in such patients and laser-assisted lead removal is an effective and safe nonthoracotomy approach. However, large vegetations (>10 mm) attached to the lead limit nonthoracotomy explantation because of the potential for hemodynamically embarrassing pulmonary embolization. Laser extraction of leads with vegetation area >300 mm2 has rarely been reported. In this case report, we describe a patient with an infected ICD lead with vegetation greater than 41 × 12.5 mm (512 mm2) in size that was explanted with laser-assistance. The resulting pulmonary embolus produced a 33 × 20 mm pulmonary infarction without hemodynamic or respiratory compromise.