Improved Discrimination of Myocardial Perfusion Defects at Low Energy Levels Using Virtual Monochromatic Imaging

    loading  Checking for direct PDF access through Ovid

Abstract

Objectives

The aim of this study was to explore the diagnostic performance of dual-energy computed tomography perfusion (DE-CTP) at different energy levels.

Methods

Patients with known or suspected coronary artery disease underwent stress and rest DE-CTP and single-photon emission computed tomography. Images were evaluated using monochromatic data, and perfusion defects were initially identified in a qualitative manner and subsequently confirmed using attenuation levels.

Results

Thirty-six patients were included. Sensitivity, specificity, positive predictive value, and negative predictive value of DE-CTP for the identification of perfusion defects were 84.1%, 94.2%, 77.3%, and 96.2%, respectively. Perfusion defects showed significantly lower attenuation than normal segments, with the largest differences among low energy levels (sensitivity of 96% and specificity of 98% using a cutoff value ≤ 153 Hounsfield units at 40 keV), progressively declining at the higher levels (P < 0.001).

Conclusions

Dual-energy CTP at the lowest energy levels allowed improved discrimination of perfusion defects compared with higher energy levels.