Unrecognized Left Heart Failure in LVAD Recipients: The Role of Routine Invasive Hemodynamic Testing

    loading  Checking for direct PDF access through Ovid

Abstract

The role of routine right heart catheterizations (RHCs) in left ventricular assist device (LVAD) patients is undefined. We analyzed 105 continuous-flow LVAD recipients who underwent an RHC approximately 3 months after implant. In 38 patients, LVAD speed was ramped with the goal of optimizing hemodynamics. Our cohort consisted of 71 (68%) HeartMate II (HMII) and 34 (32%) HeartWare (HVAD) patients. Thirty patients (29%) had either a reduced cardiac index (CI ≤ 2.2 L/min/m2), elevated pulmonary capillary wedge pressure (PCWP > 18 mm Hg), or both. A subgroup of 38 patients (19 with abnormal hemodynamics) underwent LVAD ramping. With LVAD ramping, normalization of hemodynamics was achieved in 13 (68%) patients with abnormal hemodynamics. In ramped patients, the CI increased from 2.1 L/min/m2 (2.0–2.3) to 2.5 L/min/m2 (2.3–2.6; p = 0.004), and the PCWP dropped from 21 mm Hg (20–26) to 18 mm Hg (14–21, p < 0.001). The 6-minute walk distance improved from 338 m (253–394) to 353 m (320–442, p = 0.041). A 400 rpm change in HMII speed was like a 130 rpm change in HVAD speed and led to a change in cardiac output (CO) of 0.3 L/min. The correlation between device-reported flow and measured CO for both the HMII (Rs = 0.50, p < 0.001) and HVAD (Rs = 0.47, p < 0.001) was moderate. At 3 months after LVAD implant, most patients have normal hemodynamics. Of those patients with abnormal hemodynamics, LVAD ramping results in normalization of hemodynamics and improvement in 6-minute walk distance.