Effect of pressure-controlled inverse ratio ventilation on dead space during robot-assisted laparoscopic radical prostatectomy: A randomised crossover study of three different ventilator modes

    loading  Checking for direct PDF access through Ovid

Abstract

BACKGROUND

Pressure-controlled inverse inspiratory to expiratory ratio ventilation (PC-IRV) is thought to be beneficial for reducing the dead space volume.

OBJECTIVE

To investigate the effects of PC-IRV on the components of dead space during robot-assisted laparoscopic radical prostatectomy (RLRP).

DESIGN

A randomised crossover study of three different ventilator modes.

SETTING

A single university hospital from September 2014 to April 2015.

PATIENTS

Twenty consecutive study participants undergoing RLRP.

INTERVENTIONS

Patients were ventilated sequentially with three different modes in random order for 30 min: volume control ventilation (VCV; inspiratory to expiratory ratio 0.5), pressure control ventilation (PCV; inspiratory to expiratory ratio 0.5) and PC-IRV. Inverse inspiratory to expiratory ratio was adjusted individually by observing the expiratory flow-time wave to prevent the risk of dynamic pulmonary hyperinflation.

MAIN OUTCOME MEASURES

The primary outcome included physiological dead space (VDphys), airway dead space (VDaw), alveolar dead space (VDalv) and shunt dead space (VDshunt). VDphys was calculated by Enghoff's method. We also analysed respiratory dead space (VDresp) and VDaw using a novel analytical method. Then, VDalv and VDshunt were calculated by VDalv = VDresp − VDaw and VDshunt = VDphys − VDresp, respectively.

RESULTS

The VDphys/expired tidal volume (VTE) ratio in PC-IRV (29.2 ± 4.7%) was significantly reduced compared with that in VCV (43 ± 8.5%) and in PCV (35.9 ± 3.9%). The VDshunt/VTE in PC-IRV was significantly smaller than that in VCV and PCV. VDaw/VTE in PC-IRV was also significantly smaller than that in VCV but not that in PCV. There was no significant change in VDalv/VTE.

CONCLUSION

PC-IRV with the inspiratory to expiratory ratio individually adjusted by the expiratory flow-time wave decreased VDphys/VTE in patients undergoing RLRP.

TRIAL REGISTRATION

University Hospital Medical Information Network in Japan 000014004.