Comparison of translabial three-dimensional ultrasound with magnetic resonance imaging for measurement of levator hiatal biometry at rest

    loading  Checking for direct PDF access through Ovid

Abstract

Objectives

To compare translabial three-dimensional (3D) ultrasound with magnetic resonance imaging (MRI) for the measurement of levator hiatal biometry at rest in women with pelvic organ prolapse, and to determine the interobserver reliability between two independent observers for ultrasound and MRI measurements.

Methods

Data were derived from a multicenter prospective cohort study in which women scheduled for conventional anterior colporrhaphy underwent translabial 3D ultrasound and MRI prior to surgery. Intraclass correlation coefficients (ICCs) were calculated to estimate interobserver reliability between two independent observers and determine the agreement between ultrasound and MRI measurements. Bland–Altman plots were created to assess the agreement between ultrasound and MRI measurements.

Results

Data from 139 women from nine hospitals were included in the study. The interobserver reliability of ultrasound assessment at rest, during Valsalva maneuver and during contraction and of MRI assessment at rest were moderate or good. The agreement between ultrasound and MRI for the measurement of levator hiatal biometry at rest was moderate, with ICCs of 0.52 (95%CI, 0.32–0.66) for levator hiatal area, 0.44 (95%CI, 0.21–0.60) for anteroposterior diameter and 0.44 (95%CI, 0.22–0.60) for transverse diameter. Levator hiatal biometry measurements were statistically significantly larger on MRI than on translabial 3D ultrasound.

Conclusions

The agreement between translabial 3D ultrasound and MRI for measurement of the levator hiatus at rest in women with pelvic organ prolapse was only moderate. The results of translabial 3D ultrasound and MRI should therefore not be used interchangeably in daily practice or in clinical research.